Technical data

Moisture meter

GMP 2-15

Article number

‎3 601 K78 1..‎‎‎‎

Material moisture measuring procedure

Resistance measurement

Measuring range

Relative humidity

5 % to 95 %

Ambient temperature

−20 °C to +50 °C

Unit of measurement

Moisture content

%

Ambient temperature

°C

Measuring accuracy (typical)

Conductivity (material moisture content)A)

±1 %

Relative humidityA) at:

  • 5 % to 90 %

±3 %

  • 91 % to 95 %

±5 %

Ambient temperature

±1 °C

General

Operating temperature

−20 °C to +50 °C

Storage temperature (without rechargeable battery)

−20 °C to +70 °C

Max. relative humidity (non-condensing)

95 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2B)

Power supply

  • Lithium-ion battery pack

3.7 V

  • Non-rechargeable batteries (alkaline manganese)

2 × 1.5 V LR6 (AA)

Operating time, approx.C)

  • With lithium-ion battery pack

25 h

  • With non-rechargeable batteries (alkaline manganese)

40 h

WeightD)

0.19 kg

Dimensions (length × width × height)

235 × 62 × 44.5 mm

Protection rating

IP65

Lithium-ion battery pack

BA 3.7V 1.0Ah A

Article number

1 607 A35 17H

Charging connection

USB Type‑C®

Recommended USB Type-C® cable

‎1 600 A01 6A8

Rated voltage

3.7 V

Capacity

1.0 Ah

Recommended ambient temperature during charging

+10 °C to +35 °C

Recommended ambient temperature during operation and during storage

–10 °C to +45 °C

Power supply (accessory)

Output voltage

5.0 V

Minimum output current

500 mA

A)

At an operating temperature of 25 °C

B)

Normally only non-conductive pollution occurs, although occasional temporary conductivity caused by condensation can be expected. Allow the measuring tool to acclimatise and remove condensation from the probe tips before taking a measurement.

C)

At 23 °C (±2 °C) and medium screen brightness

D)

Weight without lithium-ion battery pack/non-rechargeable batteries

Material moisture measuring range

Material

Minimum

MaximumA)

Wooden materials:

<Construction wood>

6.7 %

100.0 %

<Abachi>

6.1 %

97.1 %

<Abura>

5.7 %

100.0 %

<Afzelia>

6.1 %

75.9 %

<Agba>

5.1 %

94.2 %

<Alder>

6.7 %

94.0 %

<Ash>

7.7 %

95.8 %

<Beech>

6.2 %

93.2 %

<Birch, european>

4.6 %

95.9 %

<Cherry, american>

6.6 %

96.1 %

<Cherry, european>

5.8 %

95.4 %

<Douglas fir, american>

6.7 %

90.4 %

<Douglas fir, european>

7.7 %

85.9 %

<Elm, european>

6.4 %

88.8 %

<Fir>

8.4 %

91.1 %

<Iroko>

6.4 %

85.5 %

<Larch>

7.0 %

100.0 %

<Limba>

7.5 %

91.8 %

<Makore>

6.7 %

88.7 %

<Maple, american>

6.3 %

90.5 %

<Maple, european>

6.2 %

99.3 %

<Meranti>

6.9 %

94.1 %

<Oak red>

5.4 %

99.4 %

<Oak, american>

5.9 %

99.7 %

<Oak, european>

6.9 %

97.5 %

<Pine ponderosa>

8.2 %

96.2 %

<Pine, european>

7.3 %

97.4 %

<Poplar>

7.1 %

98.5 %

<Spruce>

8.0 %

97.3 %

<Teak burma>

7.0 %

85.1 %

<Teak plantation>

7.0 %

56.6 %

<Walnut, american>

6.5 %

98.2 %

<Walnut, european>

6.0 %

95.5 %

<Western red cedar, canadian>

5.3 %

96.0 %

<Western red cedar, european>

6.9 %

96.0 %

<Willow>

7.5 %

100.0 %

<Yew>

7.2 %

71.9 %

Construction materials:

<Anhydrite screed>

0.1 %

9.2 %

<Brick>

0 %

20 %

<Cement mortar>

0.2 %

9.7 %

<Cement screed>

0.2 %

6.6 %

<Concrete filler>

0.6 %

7.1 %

<Concrete screed>

0.1 %

6.7 %

<Drywall>

0.1 %

28.8 %

<Gas concrete>

0.8 %

75.5 %

<Gypsum>

0.1 %

29.6 %

<Lime mortar>

0.1 %

12.2 %

A)

Measured values above 80 % are shown as "> 80 %" in the display.