Technical data
Digital laser measure | GLM50-21 |
|---|---|
Article number | 3 601 K75 3.. |
Measuring rangeA) | 0.15−50 m |
Measuring range (unfavourable conditions)B) | 0.15−10 m |
Measuring accuracyA) | ±1.5 mm |
Measuring accuracy (unfavourable conditions)B) | ±3.0 mm |
Smallest display unit | 1.0 mm |
Measuring time | 0.5 s−4.2 s |
General | |
Operating temperature | −10 °C to |
Storage temperature | −20 °C to |
Relative air humidity max. | 90 % |
Max. altitude | 2000 m |
Pollution degree according to IEC 61010-1 | 2C) |
Laser class | 2 |
Laser type | 635 nm, |
Divergence of the laser beam | < 1.5 mrad |
WeightD) | 0.06 kg |
Dimensions (L × W × H) | 100 × 43 × 24 mm |
Unit of measurement setting | m / cm / |
Batteries | 2 × 1.5 V LR03 (AAA) |
Rechargeable batteries | 2 × 1.2 V HR03 (AAA) |
- A)
When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 20 °C operating temperature; a distance-dependent deviation of ±0.05 mm/m must additionally be factored in.
- B)
When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), strong background lighting, 20 °C operating temperature and high elevation. In addition, a deviation of ±0.15 mm/m must be taken into account, depending on the distance.
- C)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
- D)
Weight without non-rechargeable batteries/rechargeable batteries
The serial number (8) on the type plate is used to clearly identify your measuring tool.