Technical Data
Infrared thermometer | GIS800‑16 |
|---|---|
Article number | 3 601 K83 B.. |
Working range | 0.1−5 m |
Measuring rangeA) | −40 °C to +800 °C |
Temperature resolution | 0.1 °C |
Optics (measuring distance : measured surface ratio)B)C) | 20 : 1 |
Size of display | 2.4" |
Laser class | 2 |
Laser type | < 1 mW, 640−660 nm |
Divergence of the laser beam (full angle) | < 1.5 mrad |
Max. altitude | 2000 m |
Pollution degree according to IEC 61010-1 | 2D) |
Relative air humidity max. | 90 % |
Power supply | |
| 10.8 V/12 V |
| 4 × 1.5 V LR6 (AA) |
| 4 × 1.2 V HR6 (AA) |
Operating time | |
| 18 h |
| 12 h |
WeightG) | 0.36 kg |
Dimensions (length × width × height) | 119 × 73 × 212 mm |
Protection ratingH) | IP54 |
Recommended ambient temperature during charging | 0 °C to +35 °C |
Permitted ambient temperature during operation | –10 °C to +50 °C |
Permitted ambient temperature during storage without a rechargeable battery | –20 °C to +70 °C |
Permitted ambient temperature during storage with a rechargeable battery | –20 °C to +50 °C |
Recommended rechargeable batteries | GBA 10.8V… |
Recommended battery chargers | GAL 12… |
- A)
Maximum measuring range of the measuring tool – with contact temperature measurements, the temperature probe in use can have a smaller measuring range.
- B)
In accordance with standard VDI 5585 (average)
- C)
Refers to infrared measurement, see figure:

- D)
Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
- E)
Depending on battery in use
- F)
At an ambient temperature of 20–30 °C
- G)
Weight without lithium-ion rechargeable battery/battery adapter/non-rechargeable batteries (you can find the weight of the lithium-ion battery at www.bosch-professional.com.)
- H)
excluding lithium-ion battery pack/non-rechargeable batteries/rechargeable batteries, in the vertical position
The serial number (9) on the type plate is used to clearly identify your measuring tool.
Measuring accuracy
At measured value | At aperture | At measuring distance | Measuring accuracy |
|---|---|---|---|
Surface temperatureA) | |||
−40 °C to −30.1 °C | 50 mm | 10 cm to 50 cm | ±5.0 °C |
−30 °C to −20.1 °C | 57 mm | 10 cm to 50 cm | ±4.5 °C |
−20 °C to −10.1 °C | 57 mm | 30 cm to 100 cm | ±3.5 °C |
−10 °C to 0 °C | 152 mm | 30 cm to 100 cm | ±2.5 °C |
+0.1 °C to +100 °C | 152 mm | 30 cm to 100 cm | ±1.5 °C |
+100.1 °C to +500 °C | 152 mm | 30 cm to 100 cm | ±1.5 % |
+500.1 °C to +800 °C | 50 mm | 10 cm to 50 cm | ±1.5 % |
Contact temperature (only with type K temperature probe)B) | |||
−40 °C to +333 °C | − | − | ±2.5 °C |
+333.1 °C to +400 °C | − | − | ±0.75 % |
- A)
At an ambient temperature of +21 °C to +25 °C, an emissivity of ≥ 0.95, with worklight and laser switched off; plus usage-dependent deviation (e.g. reflection)
- B)
according to IEC EN 60584‑1: Type K, Class 2